Third Party Imaging using MDT WinPE causes imaging loop

  • 7009181
  • 15-Aug-2011
  • 27-Apr-2012

Environment

Novell ZENworks 11 Configuration Management Imaging
Novell ZENworks 10 Configuration Management Imaging

Situation

Third Party Imaging using MDT WinPE causes imaging loop.
The machine reboots and begins imaging again.
Just Imaged Flag is not being set.

Resolution

Two Command Line Options have been integrated inside zenworktodo app:  zenworktodo.exe /setJustImaged  zenworktodo.exe /clearWorkToDo   
This is fixed in version 10.3.4 - see KB 7008244 "ZENworks Configuration Management 10.3.4 - update information and list of fixes" which can be found at https://www.novell.com/support
 
This is fixed in version 11.1 - see KB 7008746 "ZENworks Configuration Management 11.1 - update information and list of fixes" which can be found at https://www.novell.com/support