Environment
Novell
ZENworks 7 Server Management Support Pack 1 - ZSM7 SP1
Novell ZENworks
Desktop Management 6.5 - ZDM6.5 Remote ManagementNovell
ZENworks Desktop Management 7 - ZDM7 Remote Management
Situation
Whenever Remote Control is started with a workstation, by default numlock is switched off on the machine being controlled during the session. When the session ends, if the num lock had previously been on, it is switched back on again.
Resolution
For ZDM7: Fixed in ZENworks 7 Desktop Management Service Pack 1 Interim Release 3a, available at https://download.novell.com
For ZDM6.5: Fixed in Novell ZENworks 6.5 Desktop Management Support Pack 2 Interim Release 1 - see KB 3665027 "Updates to Novell ZENworks 6.5 Desktop Management" at https://www.novell.com/support
In the
Registry of the Agent machine (the one to be controlled), create a
DWORD:
HKLM\Software\Novell\ZENworks\Remote
Management\RMAgent,"SyncNumKey"
If the value
is set to:
0 - (or if the value
does not exist) the NUMLOCK will be switched
off.
1 - will
ensure that the state of NUMLOCK matches that of the
controlling workstation.
2 - NUMLOCK status will be retained on
CONSOLE/AGENT.Additional Information
Note
this fix does not work for an agent running on Windows98