500 error while navigating to LoadTest application of Performance Center

  • KM03604327
  • 01-Mar-2020
  • 27-Mar-2020

Summary

500 error while navigating to LoadTest application of Performance Center

Error

500 - Internal Server Error.

There is a problem with the resource you are looking for, and it cannot be displayed

image text

Cause

The cause is that URL Re-write module is enabled/installed on the Performance Center Server machine.

There are different ways you can detect if URL Rewrite is installed on the server:

1. By looking at the following registry: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\IIS Extensions\URL Rewrite. The presence of this registry means it is installed.

URL_Rewrite-Regedit

2. Reviewing the list of programs/features installed by using the Add/Remove Program feature in the Window's Control Panel.

URL_Rewrite-ControlPanel

3. Check the existence of the URL Rewrite icon from the IIS Manager

URL_Rewrite-IIS

Fix

Disable/uninstall the IIS URL Rewrite Module 2 on the PCS machine.

IIS URL Rewrite Module 2 can be uninstalled from the PC Server machine by using the Add/Remove Program feature in the Window's Control Panel.