This document has not been formally reviewed for accuracy and is provided "as is" for your convenience.
Summary
From DP10.03, the omniusers command is necessary to execute after installing
Question
From DP10.03, the omniusers command is necessary to execute after installing
Answer
after installing 10.03 to cm(HP-Unix) and gui(Windows 10),an error occurred when access to gui.the error message is "[154:64450] User Authentication failed"then the customer resolve the problem with the action below1.add user by omniusers -add -type W -usergroup admin -name "*" -group "*" -client "*" -desc "Any"2.set password by omniusers -resetpass -name "***".can access gui successfully3.delate password by omniusers -clearpass,the error occurred againby the way ,I have reproduced this problem in my lab (cm and gui are all windows server 2012)So,if after the install of DP 10.03, it is necessary to run the omniusers -resetpass commandthe customer think it's necessary to be written in the DP’documentsPlease also consider visiting the web-based version of this response at:https://mysupport.microfocus.com/km/KM03199074