Situation
During a P2X conversion, the job may fail during the file transfer stage with the following error:
Error: Data error (cyclic redundancy check)
Resolution
This error usually indicates a problem with the disk or filesystem on the source machine.
- On the source machine, open a DOS window and run CHKDSK /R on all volumes
- Attempt the conversion again.
- If the error still occurs after retrying the conversion, this could indicate a possible hardware issue. Please obtain a disk diagnostic utility from the hardware vendor and verify that the hard disks are functioning correctly.