Environment
This article discusses an issue that can occur during the take control of the source server process.
Applies to: PowerP2V V4.0.2 and higher
Situation
When performing a conversion with the PowerP2V Server installed on a Windows 2003 Service Pack 1 server, the conversion job fails at Step 6.3.1: Taking Control and the following error is displayed:
Failed
Unable to take control of server
The request failed with HTTP status 401: Unauthorized.
Started: 02/05/2005 1:07:08 PM
Completed: 02/05/2005 1:10:36 PM
Resolution
As per Microsoft KB896861, this is most likely to occur if the Default Web site in IIS where the PowerP2V Server is installed uses Integrated Authentication and has a name that is mapped to the local loopback address.
To resolve the issue, please refer to the recommended methods outlined in KB896861:
http://support.microsoft.com/default.aspx?scid=kb;en-us;896861
If you have any questions regarding this, please contact the PlateSpin Technical Support team.