Environment
NetIQ AppManager 6.x
NetIQ AppManager 7.0.x
NetIQ Control Center 7.0.x
Situation
Receive a BITS 80072ee7 error when you attempt to check a package into the Control Center. Check in fails.
Resolution
In order to correct this issue the server name setting for the deployment settings needs to be set correctly. This can be fixed in the following manner:
- In the Control Center goto Options > Deployment > General
- Check the 'server name' field and verify that it is pointing to the correct deployment server
- The server name should NOT include any prefix (i.e. HTTP://, HTTPS://, etc)
After correcting the 'server name' entry and verifying that the BITS service is running on the server the check in process should complete successfully.
Cause
The Control Center deployment configuration improperly configured.
Additional Information
Formerly known as NETIQKB72859