When clicking in the Monitor Console the user receives this error: The stub received bad data (NETIQKB71733)

  • 7771733
  • 20-Aug-2009
  • 04-Sep-2009

Environment

Security Manager 5.x

Security Manager 6.x

Situation

When clicking in the Monitor Console the user receives this error: The stub received bad data

Resolution

The problem here is that the remote console machine does not have the same hotfix and/or service pack level as the Central Computer. To validate this, you can perform the following steps:

 

  1. Go to Program Files\NetIQ Security Manager\Onepoint on the Central Computer and console machines
  2. Get properties on SMCommon.dll file on the Central Computer and console machines.
  3. Go to the Version tab and compare the version on both the console machine and Central Computer

 

If the version is different, then apply the correct hotfix and service pack level so that both of these numbers match and that should resolve the issue.

Cause

This is caused by the hotfix or service pack level being different than the one applied to the Central Computer.

Additional Information

Formerly known as NETIQKB71733