Template parameters are empty after editing a security check. (NETIQKB71291)

  • 7771291
  • 09-Oct-2008
  • 06-Apr-2012

Environment

NetIQ Secure Configuration Manager 5.7

NetIQ Secure Configuration Manager 5.6

Situation

After editing and saving a security check the templates that the check has been added to are now missing their parameters. The version count of the template has gone past 10 once the check was updated and every template that was linked to the edited check seems to have a version of over 10 and no longer has parameters in it.

Resolution

To resolve this issue apply hotfix 71291 that is available on www.netiq.com.

Cause

The version on the template increasing to a double digit such as 10 causes the template to reset.

Additional Information

Formerly known as NETIQKB71291