Error when opening control center (NETIQKB70530)

  • 7770530
  • 19-Jul-2007
  • 31-Dec-2007

Environment

Security Manager 6.0

Situation

error: "you have not configured the central computer responsible for trend anaylsis" when opening the control center.


The control center opens but they cannot see trend analysis reports.

Resolution

Create a login account with 25 or less characters, the character count should include domain name, backslash, and username. Eg. domainname\username

 


 

 

 

Cause

The user is logging in with an account over 25 characters.

Additional Information

Formerly known as NETIQKB70530

this will be fixed in a future release.