AdptSend:Failed tec_put_event, handle 0 Return code: -1 TEC errno: 0 (NETIQKB70272)

  • 7770272
  • 09-May-2007
  • 03-Jun-2011

Environment

NetIQ AppManager 6.x
NetIQ AppManager 7.0.x
Tivoli Connector for AppManager

Situation

AdptSend:Failed tec_put_event, handle 0 Return code: -1 TEC errno: 0
The Tivoli connector has errors when attempting to forward events from or to AppManager
Possible error messages within the connector logs:

AdptSend:Failed tec_put_event, handle 0 Return code: -1 TEC errno: 0

AdptSend:Sending event through handle 18167672.
AdptSend:Failed tec_put_event, handle 0 Return code: -1 TEC errno: 0
AdptSend:Exiting

Resolution

Update DNS with the proper server name and IP address and\or use a HOST file on the server hosting the AppManager Connector to proper name resolution.

Cause

The AppManager Connector server cannot resolve the Tivoli server via name resolution (DNS).

Additional Information

Formerly known as NETIQKB70272