Cannot run EA INFO from the CLI. (NETIQKB50256)

  • 7750256
  • 02-Feb-2007
  • 19-Jun-2007

Resolution

fact
Directory and Resource Administrator 7.5

symptom
Cannot run EA INFO from the CLI.

symptom

I receive a message when running anything from the command line interface.



symptom
Error: 'Error determining the DRA server. System error 0x800703e6 occurred.'

change
The DRA CLI is running as a published application on a Citrix Server.

cause
NetIQ Technical Support has determined that a known issue occurs when discovering a DRA server.

fix
Turn off Citrix Memory Optimization on the Citrix server or specify the DRA server by name in the command.

Additional Information

Formerly known as NETIQKB50256