Cannot run EA INFO from the CLI. (NETIQKB50256)

  • 7750256
  • 02-Feb-2007
  • 19-Jun-2007

Resolution

fact
Directory and Resource Administrator 7.5

symptom
Cannot run EA INFO from the CLI.

symptom

I receive a message when running anything from the command line interface.



symptom
Error: 'Error determining the DRA server. System error 0x800703e6 occurred.'

change
The DRA CLI is running as a published application on a Citrix Server.

cause
NetIQ Technical Support has determined that a known issue occurs when discovering a DRA server.

fix
Turn off Citrix Memory Optimization on the Citrix server or specify the DRA server by name in the command.

Additional Information

Formerly known as NETIQKB50256

Feedback service temporarily unavailable. For content questions or problems, please contact Support.