VSAU Check Baseline report inside Unix Manager returns a blank report. (NETIQKB45776)

  • 7745776
  • 02-Feb-2007
  • 20-Aug-2007

Resolution

fact
VigilEnt Security Agent for Unix 5.0

symptom
VSAU Check Baseline report inside Unix Manager returns a blank report.

symptom
VSAU Check Baseline report fails to find any data.

cause
NetIQ Technical Support has determined that the VSAU Check Baseline report has a known issue when the e-mail address supplied in the policy is not valid or the e-mail cannot complete successfully.  

fix

Service Pack 1 resolves this issue, but the readme does not state that it is resolved. Download and apply Service Pack 1 from https://www.netiq.com/support/vsm/extended/hotfixes.asp?version=500&productID=VMU.



Additional Information

Formerly known as NETIQKB45776