The 'Changes to System Values' report shows the QAUDCTL system value changed to *NONE, by program AA (NETIQKB38814)

  • 7738814
  • 02-Feb-2007
  • 08-Oct-2007

Resolution

fact
System Auditing and Reporting (SAR)

fact
VigilEnt Security Agent for PSAudit 7.5

fact
VigilEnt Security Agent for iSeries PSAudit 5.4

symptom
The 'Changes to System Values' report shows the QAUDCTL system value changed to *NONE, by program AACL23.

cause
When selecting Option 3 Stop Security Journaling, in the PA17 menu of the System Auditing and Reporting program, AACL23 is invoked and the QAUDCTL system value is set to *NONE.

fix
This is by design of the product.

Additional Information

Formerly known as NETIQKB38814