Error occurs when trying to add subsystems to the ISM to be monitored. (NETIQKB34302)

  • 7734302
  • 02-Feb-2007
  • 08-Oct-2007

Resolution

fact
VigilEnt Security Agent for iSeries 5.4/7.0

symptom
Error occurs when trying to add subsystems to the ISM to be monitored.

symptom
Error: "Invalid Subsystem."

cause
This error results when attempting to add a subsystem to be monitored by ISM that is not in any of the libraries in the Library List in use at the time. 

PSMENU replaces the user's library list with the list needed by the product.

fix

From the ISM menu, follow these steps:

  1. Press F10 to obtain a Command Line.

  2. Type ADDLIBLE XXXXXXXXXX  (where XXXXXXXXXX is the library containing the subsystem to be added), and press Enter.

  3. Select Option 6  Display/Change System Parameters.

  4. Press F7=Subsystems, enter the name of the subsystem to be added, press Enter, and then F12 to exit the Subsystem entry box.  The new subsystem will be displayed at the bottom of the Option 6 screen.


Additional Information

Formerly known as NETIQKB34302