The 'Library Analysis by Library' report shows all libraries instead selected libraries. (NETIQKB32039)

  • 7732039
  • 02-Feb-2007
  • 08-Oct-2007

Resolution

fact
VigilEnt Security Agent for AS/400 5.3/6.3

fact
VigilEnt Security Agent for iSeries 5.4/7.0

fact
VigilEnt Security Agent for iSeries PSAudit

fact
VigilEnt Security Manager 3.0

fact
VigilEnt Security Manager 3.0 SR1

fact
VigilEnt Security Manager 3.0 SR2

symptom
The 'Library Analysis by Library' report shows all libraries instead selected libraries.

symptom
PS* is the parameter used to select which libraries to report on.

fix
This is a known problem. Version 5.3/6.3 PTF 1A00128 and version 5.4/7.0 PTF 1A01525 resolves the problem. See the Support section of NetIQ.com site for the PTF's or contact Technical Support.

Additional Information

Formerly known as NETIQKB32039