Resolution
fact
VigilEnt Security Agent for AS/400 PSSecure 6.3
symptom
Unable to access Secure Menuing System
cause
The group job control in Secure Menuing System is set to "No" instead of "Yes".
fix
VigilEnt Security Agent for AS/400 PSSecure 6.3
symptom
Unable to access Secure Menuing System
cause
The group job control in Secure Menuing System is set to "No" instead of "Yes".
fix
To grant access to the Secure Menuing System application change the group job control value to "Yes". Refer to the following steps to change the value:
- At a command line type: WRKDTAARA and press F4 to prompt.
- Indicate MSDEFAULT in the 'Data Area' field.
- Indicate PSCOMMON in the 'Library' field, press Enter.
- Type 2=Change next to the data area MSDEFAULT.
- Indicate *Yes in the 'New Value' field, press Enter.
Additional Information
Formerly known as NETIQKB31312