Data is not present when running the 'Crt, Chg, Restore of User Profiles' report and directing the o (NETIQKB31260)

  • 7731260
  • 02-Feb-2007
  • 08-Oct-2007

Resolution

fact
VigilEnt Security Agent for iSeries PSAudit 5.4

fact
VigilEnt Security Agent for AS/400 PSAudit 5.3

fact
System Auditing and Reporting (SAR) 

symptom
Data is not present when running the 'Crt, Chg, Restore of User Profiles' report and directing the output to a spool file.

symptom
Changes made to the 'Supplemental Groups' parameter of the user profile are not shown on the 'Crt, Chg, Restore of User Profiles' report.

cause
The Spool file output is restricted to 132 columns.  This report can contain an unusually large amount of data and could exceed the column limit for spool files.  As a result, not all of the security information collected can be displayed simultaneously.

fix
To resolve this issue, direct the report results to an output (physical) file via the normal report submittal window so that all information can be available using query tools.

Additional Information

Formerly known as NETIQKB31260