PSAudit browser report requests are running correctly, and then hang with no error messages or resul (NETIQKB30890)

  • 7730890
  • 02-Feb-2007
  • 18-May-2007

Resolution

fact
VigilEnt Security Agent for iSeries 5.4/7.0

fact
PSAudit Browser

symptom
PSAudit browser report requests are running correctly, and then hang with no error messages or result.

symptom
Reports do not complete.

symptom
PSAudit browser is configured according to instructions in the PSAudit User Guide.

fix
The PSAudit browser configuration steps available in the current PSAudit User Guide (print date: 12/10/2001) have an incorrect value for the 'Port' field within the "Register Agents" section on page 2-14. Step 6 says that "The default port number is 8080." It should read "...port number 1622." Verify that you have registered the agent with the correct port number and run your reports again.

Additional Information

Formerly known as NETIQKB30890