Resolution
goal
How do I retrieve my Object Authority Management templates that appear to have been lost?
fact
VigilEnt Security Agent for iSeries
symptom
Object Authority Management templates were lost in 5.4/7.0 upgrade.
cause
How do I retrieve my Object Authority Management templates that appear to have been lost?
fact
VigilEnt Security Agent for iSeries
symptom
Object Authority Management templates were lost in 5.4/7.0 upgrade.
cause
This is a known issue that was addressed by PTF 1S01515. However, if the backup library created during the upgrade was not named PSSTEMP
, the programs associated with the templates were not retrieved (this library may have been named PSSTEMP001
or 002
).
fix
The templates can be retrieved by following these steps:
- Locate file,
PSSECURE/AT01P
, which contains the names of the templates in the second field labeledA01
. - Make note of all of the template names.
- Go to the most recent version of library,
PSSTEMP###
, and find the programs that have the matching names to the templates. - Copy them from
PSSTEMP###
toPSSECURE
. Be sure the "Owner" of the programs isPSOBJOWNS
once they are copied back toPSSECURE
.
Additional Information
Formerly known as NETIQKB30800