The STROAMAPI command from Object Authority Management is not working. (NETIQKB30799)

  • 7730799
  • 02-Feb-2007
  • 14-Apr-2008

Resolution

fact
VigilEnt Security Agent for AS/400 5.3/6.3

fact
Object Authority Management (OAM)

symptom
The STROAMAPI command from Object Authority Management is not working.

symptom
Cumulative PTF 10227-1 seems to have delete all Security templates.

change
Cumulative PTF 10227-1 was applied (specifically PTF 1S00036).

cause

With version 6.3 Cumulative PTF 01227-1 (PTF 1S00036), there is a revised version of the STROAMAPI command. It should have replaced the copy in library, QGPL, but it did not.



fix

To resolve, follow these steps:

  1. Delete the STROAMAPI command in library QGPL.

  2. Use the CRTDUPOBJ command to create a copy of PSSECURE/STROAMAPI, and place it in QGPL.

The security templates will then be available again. This was resolved in the last CUM PTF/Service Pack for 5.3/6.3 - 1X01355.