Inactive Session Monitor subsystem, ZASBS, ends immediately with an error. (NETIQKB30771)

  • 7730771
  • 02-Feb-2007
  • 08-Oct-2007

Resolution

fact
VigilEnt Security Agent for iSeries

symptom
Inactive Session Monitor subsystem, ZASBS, ends immediately with an error.

symptom
Error: 'An error has occurred with program ASCL08. If this problem persists please contact Pentasafe Technical support.'

symptom
The error occurs when trying to start the subsystem, ZASBS.

cause
This could be an authority issue.

fix
Submit the following commands to be sure the authority is set properly:

  1. CHGPGM PGM(PSSECURE/ASCL08) USRPRF(*OWNER)

  2. CHGOBJOWN OBJ(PSSECURE/ASCL08) OBJTYPE(*PGM) NEWOWN(PSOBJOWNS)

  3. GRTOBJAUT OBJ(PSSECURE/ASCL08) OBJTYPE(*PGM) USER(*PUBLIC) AUT(*USE)


Additional Information

Formerly known as NETIQKB30771