Unable to use value *ALL for the Data Auditing and Reporting, Change report when using F8 from the ' (NETIQKB30721)

  • 7730721
  • 02-Feb-2007
  • 08-Oct-2007

Resolution

fact
VigilEnt Security Agent for iSeries

fact
VigilEnt Security Agent for iSeries PSAudit 5.4

fact
VigilEnt Security Agent for AS/400 PSAudit 5.3

symptom
Unable to use value *ALL for the Data Auditing and Reporting, Change report when using F8 from the 'Work With Files' screen. 

symptom
Error: 'File *ALL in library PSCOMMON does not exist or you are not authorized to it.'

fix
This issue is resolved with the PTFs noted below. Obtain the PTF for the version of the product you have installed from the support section of NetIQ.com or request it from Technical Support.

  • 1A00133 for 5.3
  • 1A01530 for 5.4


Additional Information

Formerly known as NETIQKB30721