Do I need to execute a 'cycle' step after applying AS/400 version 5.4/7.0 Service Pack 02098? (NETIQKB30643)

  • 7730643
  • 02-Feb-2007
  • 08-Oct-2007

Resolution

goal
Do I need to execute a 'cycle' step after applying AS/400 version 5.4/7.0 Service Pack 02098?

fact
VigilEnt Security Agent for iSeries 5.4/7.0

fact
Service Pack 02098

fact
Remote Request Management (RRM)

fix

Note: This Service Pack has been superceded.  Contact Technical Support for the most current Service Pack. 

  1. Before the restart of subsystems/modules section (Step 11, page 4 of instructions), access Remote Request Management (RRM), Option 30 Manage RRM and take Option 3 Cycle Remote Servers.

  2. Indicate *FILE and *DATABASE   for Application Server, and press Enter.

  3. Additional fields are presented.

  4. For "Allow ending subsystems" fill in QSERVER, and press Enter. This step was inadvertently left out of the instructions and will be added.

  5. Previous to CUM 02098, the additional fields did not display with the *ALL option for Application Server.

  6. For IBM OS V5R1 and subsequent OS releases, subsystem QUSRWRK will also be ended and restarted.


Additional Information

Formerly known as NETIQKB30643