Resolution
fact
VigilEnt Security Agent for iSeries 5.4/7.0
symptom
Upgrade to 5.3/6.3 is failing.
symptom
PSAudit library cannot be renamed.
fix
VigilEnt Security Agent for iSeries 5.4/7.0
symptom
Upgrade to 5.3/6.3 is failing.
symptom
PSAudit library cannot be renamed.
fix
- From a command line, type
WRKJRN
for *All journals in the PSAUDIT library. If found, use the following command:ENDJRNPF File(*all) Jrn(PSAUDIT/jrnname)
- If the journal found is not needed, delete it.
- If it is not a PentaSafe journal, it should not be in a PentaSafe library. Technical Support suggests moving it, along with any receivers associated with it. (If the journal and associated receivers are named
AAMON
, they can be deleted). - On a command line, type:
WRKJRNRCV JRNRCV(PSAUDIT/*ALL)
This command can be used to find any journal receivers in the library that could be contributing to conflict.
- Start the upgrade again.
Additional Information
Formerly known as NETIQKB30640