Error message found in the PSOBJOWN user profile joblog CPF1136 Duplicate entries in LIbrary list (NETIQKB29715)

  • 7729715
  • 02-Feb-2007
  • 08-Oct-2007

Resolution

fact
See Knowldege Base article NETIQKB30778 for instructions on how to obtain joblogs for iSeries requests submitted via VSM if needed for review.

fact
VigilEnt Security Agent for iSeries 5.4/7.0

fact
Trying to connect to the iSeries agent via VSM console.

fact
VigilEnt Security Manager

fact
VigilEnt Security Manager 4.0

fact
VigilEnt Security Manager 4.1

symptom
Error message: 'CPF1136 Duplicate entries in LIbrary list for QGPL' received in the PSOBJOWN user profile joblog.

symptom
PSEAGENTD job in ZPSE  subsystem starts but ends immediately.

symptom
Agent connection refused message on VigilEnt Security Manager Console. Bind error noted.

cause
If library QGPL is in the System Library List, it cannot be added to the Initial Library list like Job Description PSEAGENTD attempts to do.

fix
Remove QGPL from the library list in job description PSEAGENTD using CHGJOBD command. 

note
There will eventually be a programmatic change made to handle this issue in the future.

Additional Information

Formerly known as NETIQKB29715