Environment
NetIQ PlateSpin Protect 11.x
NetIQ PlateSpin Forge 4.x, 11.x
NetIQ PlateSpin Migrate 12.x
Situation
After a nss rebuild, the an incremental job fails with “An unexpected error has occurred”
Resolution
Run a new full replication for the workload.
Cause
When a nss rebuild is run the .blocks_bitmap file is no longer valid as the underlying structure of the disk was changed at a block level by the rebuild.
Additional Information
After creating diagnostics for the failed job the error shown is “Input stream ended unexpectedly for file: . See diagnostics for details.”