Situation
Posted Note modified on device automatically moves one day behind
Resolution
Follow the steps listed below on GroupWise Mobility Server 2.0.1 Build 53
-
Make sure that the version of Mobility server installed is 2.0.1.53 by typing cat /opt/novell/datasync/version
-
Download and extract util.pyc, convert.pyc and calendar.pyc from
ftp://ftp.novell.com/outgoing/883449.zip -
Stop Mobility by typing rcgms stop
-
Browse to /opt/novell/datasync/syncengine/connectors/mobility/lib/conv and rename util.pyc to util.orig
-
Copy the extracted util.pyc to /opt/novell/datasync/syncengine/connectors/mobility/lib/conv
-
Browse to /opt/novell/datasync/syncengine/connectors/mobility/lib/conv/as2se and rename convert.pyc to convert.orig
-
Browse to /opt/novell/datasync/syncengine/connectors/mobility/lib/conv/as2se and rename calendar.pyc to calendar.orig
-
Copy the extracted convert.pyc and calendar.pyc to /opt/novell/datasync/syncengine/connectors/mobility/lib/conv/as2se
-
Start Mobility Service by typing rcgms start
Additional Information
Steps to Duplicate:
-
Login to WebAccess
-
Click New | Posted Note
-
Set the Start Date and Subject and click Post
-
Wait for the Posted Note to appear on the Device
-
Modify the Subject
-