Error: "worker ajp://127.0.0.1:9019/nidp already used by another worker"

  • 7012546
  • 04-Jun-2013
  • 04-Jun-2013

Environment

NetIQ Access Manager 3.2 Single Box Appliance
NetIQ Access Manager 3.2 Support Pack 1 applied

Situation

After installing the Access Manager single box appliance, test users were able to access the sample portal application after authenticating to the Identity Server first. Although everything appeared to be fine, the rcnovell-apache2 startup log file showed the following warnings:

[Thu May 23 11:06:04 2013] [info] worker https://10.113.64.197:8443 already used by another worker
[Thu May 23 11:06:04 2013] [info] worker ajp://127.0.0.1:9019/nidp already used by another worker

Resolution

These warnings are purely cosmetic in nature eg. the 9019 warning stems from the IDP server.xml, yet the IDP server does not use the AJP connector.