Error "Found less disks then expected" during Failback to Physical

  • 7010845
  • 27-Sep-2012
  • 01-Aug-2017

Environment

PlateSpin Forge 4.x, 11.x
PlateSpin Migrate 11.x, 12.x
Platespin Protect 11.x 

Situation

When running a Failback or migration to a physical target the job fails with this error:
 
Found less disks then expected
 
This may occur even if the target only has 1 disk total.

Resolution

To work around this issue it is necessary to fall back to the older disk validation method:
 
1. On the PlateSpin server, go to http(s)://localhost/platespinconfiguration in a web browser. 
 
 
2. Locate the setting DisableX2PDiskRuntimeValidation and change its value to true.

3. Retry the job.