How to re-extend schema in Novell BorderManager 3.9

  • 7006309
  • 21-Jun-2010
  • 26-Apr-2012

Environment

Novell BorderManager 3.9 Support Pack 1
Novell BorderManager 3.9 Support Pack 2

Situation

Logger screen shows error when using iManager to configure BorderManager, complaining about missing attributes.

Resolution

To re-extend the schema, follow this steps:

1. Verify that this files are on sys:system\schema directory:

vpnsch.ics
vpnextnd.NCF
addvpsch.bat
bmvpn.sch
dsply.sch
fso.sch
nvlplcy.sch
policy.sch
repos.sch
svc.sch
vpnr.sch

If they're not there, you can copy them from the bm39sp1 0verlay dvd.

Then from a mapped driver on a windows PC, run sys:system\schema\addvpsch.bat

Then go back to imanager and see if error is gone

if not

Go to server console and type: (verify that nwconfig is not loaded)

 
sys:system\schema\vpnextnd.NCF

 and it should finish with no errors.

Check again on imanager that now error is gone