Environment
Products:
Novell GroupWise 7 Support Pack 3 Hot Patch 3
Novell GroupWise 8 Support Pack 1
Novell GroupWise 7 Support Pack 3 Hot Patch 3
Novell GroupWise 8 Support Pack 1
GroupWise Internet Agent
Situation
Symptoms:
GWIA cannot create queues when its restarted after renaming them .
Error " Cannot find Domain directories load Message Transfer Agent", on logger screen.
GWIA cannot create queues when its restarted after renaming them .
Error " Cannot find Domain directories load Message Transfer Agent", on logger screen.
Resolution
Corrective Action:
- Launch ConsoleOne , connect to the GWIA owning Domain
- Launch GWIA properties- GroupWise- Network Address and Change the Message transfer port to 0
- Validate and Recover the Domain and restart the Domain and
GWIA. This should create new queues in the GWIA directory.
Additional Information
Notes:
The Resolution is applicable when the GWIA and its owning Domain(MTA) are on the same server.
The Resolution is applicable when the GWIA and its owning Domain(MTA) are on the same server.