Crash in prebootpolicy service with debug setting > 1

  • 7004575
  • 30-Sep-2009
  • 29-Apr-2013

Environment

Novell ZENworks 10 Configuration Management with Support Pack 2 - 10.2

Situation

Random crash under high load in prebootpolicy service novell-zmgprebootpolicy.exe
 
ERROR (from event log):
novell-zmgprebootpolicy.exe,
version 0.0.0.0, faulting module msvcr80.dll, version 8.0.50727.3053, fault
address 0x00011787.

 

Resolution

Workaround:  
 
Set policyloglevel  to minimal logging in novell-zmgprebootpolicy.conf (%ZENWORKS_HOME%\conf or /etc/opt/novell/zenworks/preboot/)
 
PolicyLogLevel=1
 
and restart the service.
 
For more information about the logging for preboot services, see KB 3418069 at support.novell.com
 

Status

Reported to Engineering

Additional Information

The Dr. Watson error showed that the problem occurred while logging unexpected information coming from zisd on a device.