Unable to log in to Sentinel Control Center

  • 7004569
  • 30-Sep-2009
  • 26-Apr-2012

Environment

Novell Sentinel 6.1 Sentinel Control Center

Situation

  • Unable to log in to Sentinel Control Center
  • Error:  The INSERT statement conflicted with the CHECK constraint "AUDIT_RECORD_P_20090929000000_DC".  The conflict occurred in database "ESEC", table "dbo.AUDIT_RECORD_P_20090929000000", column "DATE_CREATED".  (Table and record names may vary.)
  • Events not being logged to database

Resolution

Ensure that the system is not writing to the P_MAX partition.
  • Go to the Sentinel Data Manager Partitions Tab
  • Select each table in the Table drop-down in turn and check if the name of the table listed as Online Current is P_MAX
    • If it is select the Add tab and add another partition

Additional Information

Work with the Database Administrator (DBA) to ensure that the database is correctly specified and sized.