-609 Missing Mandatory Error when LUM enabling an user

  • 7001364
  • 16-Sep-2008
  • 27-Apr-2012

Environment

Novell iManager 2.7
Novell Open Enterprise Server 2 (OES 2)
Novell Open Enterprise Server (Linux based)

Situation

(Error -609) One or more of the mandatory properties for the object being created is missing. When LUM enabling an user through iManager

Resolution

The user is missing the uniqueID Attribute. Add this attribute manually and LUM enable the user again.

To add this attribute manually. In iManager go to Directory Administration | Modify Object | Select the User for which the above error does occur.
Under the General Tab click on Other.
Under the Unvalued Attributes search for the uniqueID attribute and add this with the arrow to the Valued Attributes.
Here it will ask for a value. Fill this out with the uniqueID you want to have for this user.