Environment
Novell ZENworks 10 Configuration Management 10.0.3
Novell SUSE Linux Enterprise Server 10
Windows XP SP3
Novell SUSE Linux Enterprise Server 10
Windows XP SP3
Situation
Unable to launch ZENworks 10 Admin Studio
ERROR: token is in use
Error happens when trying to run Admin Studio from an XP workstation against a ZCM 10 Zone running on a SLES 10 server.
ERROR: token is in use
Error happens when trying to run Admin Studio from an XP workstation against a ZCM 10 Zone running on a SLES 10 server.
Resolution
In this instance, the NIC on the SLES 10 SP2 server was changed to be a different NIC than the default Broadcom 5708 NIC that is installed by default on an HPDL380G4 server.
Additional Information
The communication to and from the SLES server on the Broadcom 5708 NIC appeared to be dropping packets, contributing to the token error message. Once a different NIC was used, the Admin Studio application ran without any errors.