ConsoleOne ZENworks snapin will not reselect a previously unchecked option.

  • 3947868
  • 27-Feb-2007
  • 30-Apr-2012

Environment


Novell ZENworks Desktop Management 7 - Support Pack 1 - ZDM7 Desktop Management

Situation

Within an application object the option "Distribute in Workstation Security Space if Workstation Associated" is checked by default (assuming this is not an MSI application). Unticking this box and then applying the change results in it not being possible to recheck that option.

Resolution

Fixed in ZENworks 7 Desktop Management Service Pack 1 Interim Release 3a, available at Novell Downloads

There are two possible workarounds:

1) Recreate the application object.
2) Use the older ZENworks Desktop Management 7 snappins to modify the application object.



Additional Information

Note:
This issue does not occur with MSI application objects.

Steps to Duplicate:
1) Launch ConsoleOne 1.3.6e and create an application object (not an MSI application).
2) Uncheck Distribution Options -> Options ->"Distribute in Workstation Security Space if Workstation Associated".
3) Click"Apply".
4) Recheck the option and click "Apply" again