Environment
Novell ZENworks 7
Server Management -
ZSM7 Tiered Electronic Distribution (TED)
Situation
Symptoms
A manual distribution fails when being imported on a new subscriber
Variables have not been set on the subscriber
Change
The first distribution sent to the new subscriber was a manual distribution
A manual distribution fails when being imported on a new subscriber
Variables have not been set on the subscriber
Change
The first distribution sent to the new subscriber was a manual distribution
Resolution
Send an on-line
distribution to the new subscriber.
This sends the configuration (including the variable settings) work order across.
This sends the configuration (including the variable settings) work order across.
Additional Information
The first on-line distribution would recognise configuration
information was missing and send it
The manual distribution does not contain any configuration information, and should not update variables, etc.