Workstation object Registered Time stops getting updated after ZDM upgrade

  • 3114881
  • 12-Oct-2006
  • 30-Apr-2012

Environment

Novell ZENworks for Desktops 3.2
Novell ZENworks for Desktops 4.0.1 - ZfD4.0.1
Novell ZENworks 6.5 Desktop Management - ZDM6.5
Novell ZENworks Automatic Workstation Import

Situation

DS workstation object Registered Time stops getting updated after ZENworks Desktops has been upgraded to a newer version (server and workstation).

Migration of the existing workstation object fails.

Resolution

If the workstation registered time stops getting updated, delete the 'old' workstation object in eDir, unregister the workstation, and reimport the workstation with the newer version of the ZENworks import server. The newly imported workstation has the newer ZDM version format and schema.

Additional Information


Formerly known as TID# 10096528