Environment
Novell GroupWise 7
Novell GroupWise 8
SUSE Linux Enterprise Server 10
SUSE Linux Enterprise Server 11
Novell Open Enterprise Server 1 (OES 1) Linux
Novell Open Enterprise Server 2 (OES 2) Linux
Situation
ERROR: "Error: Too many files open [820A]"
ERROR: "The database facility reported error [820A] on msg181.db"
ERROR: "Error Processing Message: [820A]"
ERROR: "MTP: Error scanning directory [820A]: /pathToPostOfficeDirectory/wpcsin/x"
Resolution
Please apply GroupWise 8 Support Pack 1 Hot Patch 1. GroupWise 8 Support Pack 1 Hot Patch 1 can be downloaded from
Please follow the instructions in the following TID to install GroupWise 8 Support Pack 1 Hot Patch 1
Workaround Steps:
Follow the steps listed below:
- Edit /etc/security/limits.conf file.
- Type the following at the bottom of the file:
* soft nofile 65535
* hard nofile 65535 - Save the file.
- Edit /etc/sysctl.conf file.
- Type the following at the bottom of the file.
fs.inode-nr = 128000
fs.file-max = 64000 - Save the file.
- Type "chkconfig boot.sysctl on" and press Enter on the Console.
- Launch ConsoleOne.
- Connect to the Domain Object.
- Highlight the Post Office Object in question.
- Use the drop-down list to display the Post Office Agents.
- Right Click on the POA object and click Properties.
- Click GroupWise | Agent Settings.
- Increase the Max. Physical Connections. Double the Physical Connections.
- Click Apply and Close.
- Restart the Server.
Change Log
2010-Dec-03: Jason Record - Added NSA Status and Logo