Error: CMC Initialization of the GroupWise domain database failed (C002).

  • 10012518
  • 4.0.218184.2170496
  • 02-Jun-1999
  • 14-Mar-2002

Fact

Novell GroupWise 5.5

GroupWise WebAccess 5.5

Symptom

Error: CMC Initialization of the GroupWise domain database failed (C002).

WebAccess will not load.

Cause

The gateway object was created in NWADMIN for NT instead of NWADMIN32.  To administer GroupWise 5.5 objects, NWADMIN32 must be used.
Refer to TID #2941811

NOTE:  Make sure the latest GroupWise and NetWare patches have been applied.

Fix

Remove and reinstall WebAccess